Avantar Single Cable Cleats are one-piece mounting devices used for securing electrical cables in position on cable ladders, trays and structural brackets. They are composed of LSFH PA66 (nylon 6.6) and withstand temperatures from -40°C to +120°C. They can do wire outer diameters from 10 mm to 90 mm. The mounting might be a snap-fit design or M8/M10 bolt fastening. The items fulfil the IEC 61914 and RoHS standards and can be used for indoor and outdoor installations where fire safety and mechanical cable restraint are critical.
The items are mechanical clamps which secure a cable to a support structure one at a time. The wire is held in place by each cleat and prevented from sliding sideways due to electromagnetic forces that occur during a short circuit.
They have full control over spacing and routing plan as installers fix wires one by one. This is especially critical for high voltage power distribution, because the distance between cables has an effect on both the amount of heat lost and the containment of faults.
LSFH PA66 polymer is used for the body of each shoe. This substance, when burnt, does not emit much smoke and does not emit any halogen gases, thus it passes the fire safety criteria in tunnels, data centers, train stops and public buildings.
The material is UV stabilised so it may be used outside without breaking down or become brittle over time. The cleat keeps its holding strength in its specified temperature range, in open outdoor runs and in enclosed indoor runs.
Key features:
| Parameter | Value |
|---|---|
| Standard | IEC 61914 |
| Material | LSFH PA66 (Nylon 6.6) |
| Cable Diameter Range | 10 mm – 90 mm |
| Mounting Bolt Size | M8 / M10 |
| Operating Temperature | -40°C to +120°C |
| Environmental Compliance | RoHS |
| UV Stability | Yes (indoor and outdoor) |
| Installation Method | Snap-fit or bolted |
The LSFH material and IEC 61914 compliance make single cable cleats a practical choice for projects where cable integrity and fire performance are both specified.
Common installation environments include:
Standard catalogue sizes cover the outside diameters of cables that are 10 mm to 90 mm. Avantar can be customised by OEMs and ODMs for projects that need specific bore sizes, mounting hole patterns, or custom colour coding to make it easier to find cables in complicated installs.
For big building bids, samples can be sent to the site to be checked out before the full production starts. This can be set up during the order process if your project needs specific test report formats, product marking, or third-party certification coordination through SGS, BV, or TÜV.
Products are made using ISO 9001 quality control and meet the requirements of IEC 61914, RoHS, and CE. Avantar also has certifications for a wide range of products from UL 486A/B to IEC 60502, IEC 60076, IEC 62561, ANSI C29.13, and IEEE 404.
A certificate of origin and IEC 61914 test results are sent with every export shipment. Options that can be chosen before placing large orders are:

To confirm the correct model and receive accurate pricing, please provide the following when contacting us:
Standard catalog items are typically dispatched within 5–10 working days after order confirmation. Quotations are available under EXW, FOB, and other common trade terms. If you are unsure of the correct size, send your cable datasheet or OD measurement and the technical team will confirm the appropriate model.

Q: Where do you see LSFH products being used most often?
A: Products made from LSFH PA66 are used in places where both fire safety and cable support are needed. Data centers, train stations, tunnels, and industrial sites that work in temperatures between -40°C and +120°C are common places to find them. The IEC 61914 rating shows that the mechanical support and short-circuit protection work.
Q: Does Avantar make things or do they sell things?
A: Avantar is a direct manufacturer. In-house injection moulding and dimensional testing of PA66 LSFH parts make it easier to respond more quickly to technical questions and requests for customisation.
Q: What kinds of maintenance options are there?
A: There are two ways to fix it: snap-fit for quick assembly in the field, and M8 or M10 bolt-on for places like railroads and factories that need to handle more shaking or mechanical load. Check the bolt and cable sizes before installing them in bulk.
Q: How can I be sure of the quality of a product before I buy a lot of it?
A: As for Q&A, you can ask for IEC 61914 test reports and RoHS compliance papers, a trial batch for on-site validation, a video inspection before shipping, or an inspection by a third party through SGS, BV, or TÜV.
Q: What is the minimum order quantity (MOQ) and how long is the wait time?
A: You need to order at least 100 of each model. Standard catalogue items are sent out 5–10 business days after the order is confirmed. You can get quotes using EXW, FOB, and other standard business terms.
Q: Can the inner bore be changed to fit cable diameters that aren't standard?
A: Yes. The normal range is from 10 mm to 90 mm. Through the OEM/ODM program, the inner clamping bore can be changed to fit cable ODs that aren't normal. Send the details of your cable for technical confirmation.

Send your cable specifications or project requirements for Single Cable Cleats to [email protected]. Our team will follow up with pricing, available documentation, and sample options.
Learn about our latest products and discounts through SMS or email